Super External Counter-pulsation Device (secp Iii)

Check Business Detail of Super External Counter-pulsation Device (secp Iii) with contact information, address, google map of their location, business city and phone number of Super External Counter-pulsation Device (secp Iii). You can find business terms and products of Super External Counter-pulsation Device (secp Iii) including fax number, contact number, email address and website. You can also check more Health And Medical business types like Super External Counter-pulsation Device (secp Iii) in China.

Name Super External Counter-pulsation Device (secp Iii)
City China
Type Health And Medical
Email [email protected]
Phone # +86-20-34712629
Mobile # +86-13719128368
Contact Person David Lin
Address NO.18, 2nd Hanxi Industrial Zone, Zhongcun, Panyu, Guangzhou, China
Description About this product: Product: Super External Counter-Pulsation Device (SECP) USAGE: The device can be used for the treatment of: (1).Coronary heart disease, angina pectoris and myocardial infarction. (2).Cerebral arteriosclerosis, cerebral thrombosis, cerebral embolism, paralysis agitation, cerebral ischemia of vertebral-basilar artery, sequel of cerebrovascular accident and other encephalopathy caused by ischemia. (3).Embolism of retinal artery, central serous retinopathy, and optic atrophy and nerve disease for shortage of blood. (4).Sudden deafness. (5).Other ischemic diseases and sequels caused by arteriosclerosis and disturbance of circulation, therapy after operation of coronary bypass. (6).Tiredness due to excessive physical exercise. (7).Rehabilitation and health-care purposes. Technical Specification 1. Common mode rejection ratio (CMRR): not less than 80 dB(resolution). 2. Automatic pick-out of the QRS, gating limit at the input terminal, not greater than 0.25 mV. Both positive and negative EC can be detected. 3. Automatically tracing the irregular heart rate, and making possible synchronized counter-pulsation. 4. In case of premature pulsation or delayed deflation, QRS wave triggers the deflation automatically. 5. In case of patient's heart rate is lower than 35 beats/min., the parameter of heart rate on screen becomes red and the ECPT stops automatically, ECPT recovers when the heart rate is normal. 6. At "ADULT" , in case of premature pulsation or the patient's heart rate exceeds 125 beats/min., the parameter of heart rate on screen becomes red and the ECPT stops automatically, and ECPT recovers when the heart rate is normal. 7. The device has 5 adjustable settings for simulated EC waves (inner triggering square waves) i.e. 40,60,80,100,120 beats/min.. In case of turning on or reset, the default setting is 80 beats/min.. 8. The device has 9 adjustable settings for treating time, i.e. 10,20,30,40,50,60,70,80,90 minutes. In case of turning on, reset or restoration of power supply, the default setting is 50 minutes. 9. The monitor displays: (1)Heart rate and starting time of inflation and deflation. (2)Treating time, pulse wave peak ratio: h2 : h1 and area ratio: Area 2 : Area 1. 10. Two settings for counter-pulsation ratio: 1:1 : 1:2. 11. Digital filtering restrains the sine 50 Hz interference signals from EC input. 12.3-trace,3-signal monitor displays the cardiac signal,inflation/deflation signal and pulse waveform synchronously. 13. Limiting inflation time against positive pulsation function is provided. 14. 2 scanning speed settings: 25mm/s and 50 mm/s are provided. 15. Electric-control of pressure regulation. 16. Automatic stop of the pump at the end of treatment. 17. Automatic deflation at the end of the treatment. 18. Power consumption: Control Console : 220V 50/60Hz 500W 110V 50/60Hz 1000W Air pump(in the bed) : 380V 50/60Hz 1850W 19. The inflation range (positive pressure) is not lower than 0-0.04MPa, negative pressure is used for deflation. 20. Upper limit of air-pressure automatically controlled. 21. The turn-off buttons for patient in emergency are fitted at each side of the device. PRINCIPLE During the treatment, the specially made inflatable balloon cuffs are wrapped and fastened to the extremities and buttocks of the patient. When the heart in the diastolic stage, the air goes into the balloons in sequence, and compresses the artery by cuffs, so that the blood in diastolic stage can concentrate to the upper part of the body, which increase the blood volume of the heart, and promote the set up of the collateral circulation gradually. After the close of arterial valves, through the deflation of the air in the balloon cuffs, the compressed artery is thus immediately release, so that it may receive the blood driven from the heart, hence the device decreases the after-load of the heart, and reduces the systolic pressure, which has the therapeutic effect on all kinds of cardiac vascular and cerebrovascular diseases caused by myocardial and cerebral ischemia.

Note: If This Business Belongs To You or Your Reference, and You Want To Add/Edit More Information, Then Please Contact Us at "[email protected]"

Rate This Business

Your Comments/Thoughts ?